EMCMD <system> GETVOLUMEDRVSTATE <volume letter>

This command retrieves the current state of the SIOS DataKeeper device driver.

The parameters are:

<system> This can be either the source or the target systems.
<volume letter> The drive letter of the volume you want to get the configuration on.

The output is a number indicating the state. The output is purposely terse as it is designed to be parsed in a DataKeeper recovery script. The output is one of the following mirror states:

-1:   Invalid State

0:   No mirror

1:   Mirroring

2:   Mirror is resyncing

3:   Mirror is broken

4:   Mirror is paused

5:   Resync is pending

The output also provides the address of the mirror end point (source or target).