EMCMD <system> READREGISTRY <volume letter>
This command tells the SIOS DataKeeper driver to re-read its registry settings.
The parameters are:
<system> | This can be either the source system or the target system. |
<volume letter> | The drive letter of the mirror for which you want to re-read settings. |
Example:
EMCMD testsystem READREGISTRY D
This command causes the following registry settings to be re-read and any changes to take effect.
Source system (changes to these parameters take effect immediately):
BandwidthThrottle
BitmapBytesPerBlock
BlockWritesOnLimitReached
CompressionLevel
ResyncReads
WriteQueueByteLimitMB
WriteQueueHighWater
WriteQueueLowWater (This value is deprecated and no longer used.)
DontFlushAsyncQueue
Target system (changes take effect the next time the source and target systems reconnect):
TargetPortBase
TargetPortIncr