EMCMD <system> SETCONFIGURATION <volume letter><configuration mask>
This command sets the net alert settings (also referred to as "volume attributes") for the volume. The parameters are:
<system> |
This can be either the source or the target system. |
<volume letter> |
The drive letter of the volume you want to set the configuration on. |
<configuration mask> |
This is a bitmask indicating the net alert settings. These bits are defined: 1 -- 0x01: All Net Alerts is enabled 2 -- 0x02: Broken State Alert is enabled 4 -- 0x04: Resync Done Alert is enabled 8 -- 0x08: Failover Alert is enabled 16 -- 0x10: Net Failure Alert is enabled 32 -- 0x20: LifeKeeper Config is enabled 64 -- 0x40: Auto Resync is enabled 128 -- 0x80: MS Failover Cluster Config is enabled 256 -- 0x100: Shared Volume is enabled |
Example to clear all flags:
EMCMD . SETCONFIGURATION E 0
Multiple Configuration Example to enable Shared Volume and MS Failover Cluster Config (add decimal values 256 + 128):
EMCMD . SETCONFIGURATION E 384