You are here: DataKeeper > Administration > Using EMCMD with SIOS DataKeeper > READREGISTRY

READREGISTRY

EMCMD <system>READREGISTRY <volume letter>

This command tells the SIOS DataKeeper driver to re-read its registry settings. The parameters are:

<system>

This can be either the source system or the target system.

<volume letter>

The drive letter of the mirror for which you want to re-read settings.

This command causes the following registry settings to be re-read and any changes to take effect.

Source system (changes to these parameters take effect immediately):

BandwidthThrottle

BitmapBytesPerBlock

CompressionLevel

ResyncReads

WriteQueueByteLimitMB

WriteQueueHighWater

WriteQueueLowWater (This value is deprecated and no longer used.)

DontFlushAsyncQueue

Target system (changes take effect the next time the source and target systems reconnect):

TargetPortBase

TargetPortIncr

of