You are here: DataKeeper > Administration > Using EMCMD with SIOS DataKeeper > GETVOLUMEDRVSTATE

GETVOLUMEDRVSTATE

EMCMD <system> GETVOLUMEDRVSTATE <volume letter>

This command retrieves the current state of the SIOS DataKeeper device driver.

The parameters are:

<system>

This can be either the source or the target systems.

<volume letter>

The drive letter of the volume you want to get the configuration on.

The output is a number indicating the state. The output is purposely terse as it is designed to be parsed in a DataKeeper recovery script. The output is one of the following mirror states:

-1: Invalid State

 0: No mirror

 1: Mirroring

 2: Mirror is resyncing

 3: Mirror is broken

 4: Mirror is paused

 5: Resync is pending

The output also provides the address of the mirror end point (source or target).

of